Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.269
Filtrar
1.
JBJS Rev ; 12(5)2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38709911

RESUMO

¼ Bony Bankart lesions are fractures of the anteroinferior glenoid rim, commonly associated with a traumatic anterior shoulder dislocation, and are diagnosed through radiological imaging and physical examination. Young male athletes playing contact sports are at highest risk of these injuries. Early diagnosis and treatment are crucial because, if left untreated, recurrent anterior shoulder instability and glenoid bone loss can occur. Both nonsurgical and surgical treatment options are available depending on the size of the lesion, with arthroscopic repair being the most common treatment method. After repair, patients typically have favorable outcomes with low rates of recurrent instability. This review aims to discuss the etiology, diagnosis, and treatment of bony Bankart lesions.¼ Bony Bankart lesions are fractures of the anteroinferior glenoid rim and occur in up to 22% of first-time anterior shoulder dislocations.¼ Young men involved in contact sports or combat training are at the highest risk of sustaining bony Bankart lesions.¼ Diagnosis and treatment of bony Bankart lesions are essential to prevent long-term shoulder instability.¼ Bony Bankart lesions can be treated either nonoperatively or operatively (arthroscopic vs open repair), with the size of the glenoid defect being the primary determinant of treatment.


Assuntos
Lesões de Bankart , Humanos , Lesões de Bankart/diagnóstico , Lesões de Bankart/terapia , Lesões de Bankart/cirurgia , Luxação do Ombro/terapia , Luxação do Ombro/diagnóstico , Luxação do Ombro/cirurgia , Artroscopia/métodos , Masculino
2.
Am J Sports Med ; 52(6): 1457-1463, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38616609

RESUMO

BACKGROUND: The use of isolated soft tissue repair versus bone block stabilization for the treatment of recurrent anterior shoulder instability in adolescents has no scientific evidence. PURPOSE: To compare the clinical outcomes of adolescent patients who underwent isolated arthroscopic Bankart (iB) repair with those who underwent the arthroscopic Bristow-Latarjet procedure in addition to Bankart (BLB) repair. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: A total of 60 shoulders in adolescents (aged 13-18 years) were reviewed with a minimum 2 years' follow-up: iB repair (n = 36) and arthroscopic Bankart repair with an additional Bristow-Latarjet procedure (BLB; n = 24). The characteristics of the patients in each group in terms of age at the first instability episode, age at surgery, hyperlaxity, participation in at-risk sports, and Instability Severity Index Score were comparable. The mean follow-up was longer in the iB group (7.7 vs 4.1 years, respectively), whereas the rates of patients engaged in competition and those with glenoid lesions were higher in the BLB group. The primary outcome measures were failure, defined as the recurrence of instability (clinical dislocation or subluxation), and return to sports. The mean follow-up was 6.2 years (range, 2-16 years). RESULTS: At the last follow-up, the rate of recurrence was significantly higher in the iB group, with 22% (8/36) failures, than in the BLB group, with 8% (2/24) instability recurrences (P < .05). The rate of return to sports at the same level was significantly higher after the BLB repair than after iB repair (79% vs 47%, respectively; P < .001). No statistical difference was found in patient-reported outcome scores between treatment groups (P > .05). Although failures occurred early after the BLB repair, 88% of failures after iB repair occurred after 2 years. On multivariate analysis, adolescents in the iB group with >3 episodes of preoperative dislocation and shoulder hyperlaxity (external rotation >90°) had a 60% recurrence rate (P < .005). CONCLUSION: Adolescent patients undergoing the BLB repair had a lower rate of recurrent instability and higher rates of return to sports and competition than those undergoing iB repair. Patients with shoulder hyperlaxity (external rotation >90°) and >3 dislocations had an unacceptable failure rate of 60% after iB repair.


Assuntos
Artroscopia , Instabilidade Articular , Recidiva , Volta ao Esporte , Articulação do Ombro , Humanos , Adolescente , Artroscopia/métodos , Feminino , Masculino , Instabilidade Articular/cirurgia , Articulação do Ombro/cirurgia , Estudos Retrospectivos , Luxação do Ombro/cirurgia , Lesões de Bankart/cirurgia
3.
J Orthop Sports Phys Ther ; 54(5): 1-13, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38506709

RESUMO

OBJECTIVE: We aimed to develop a consensus-based rehabilitation guideline specifically designed to reduce apprehension following arthroscopic Bankart repair after traumatic anterior shoulder dislocation. DESIGN: Delphi-based consensus. METHOD: A comprehensive list of interventions for potential inclusion in a postoperative rehabilitation guideline was developed. American and European physiotherapists and orthopedic surgeons were invited to participate in a Delphi panel, engaging in 3 survey rounds. The health professionals were surveyed about their level of agreement on both initially listed and newly suggested interventions. Consensus was established when a "critical-to-include" rating was given in ≥70% of all responses. Ten former patients were consulted to identify the intervention during standard care rehabilitation that had the most impact on reducing postoperative apprehension following ABR. Any interventions not initially listed in the first round were added to the second survey round of the Delphi process. RESULTS: Forty-four health professionals reached consensus on a set of 27 interventions for managing apprehension after arthroscopic Bankart repair. New interventions included gradual exposure to shoulder positions eliciting apprehension, training in anterior stability-provoking positions, and education addressing the impact of psychosocial factors. Former patients identified specific interventions that were effective in reducing postoperative apprehension following ABR. These interventions encompassed medicine ball throws, active-assisted wall slides, and kinetic chain exercises in anterior stability-provoking positions. CONCLUSION: Our Delphi process informed expert recommendations for various interventions aimed at addressing apprehension associated with ABR. The recommendations were the foundation for developing a rehabilitation guideline (REGUIDE). The REGUIDE integrates principles from cognitive-behavioral therapy to improve rehabilitation and mitigate apprehension. J Orthop Sports Phys Ther 2024;54(5):1-13. Epub 20 March 2024. doi:10.2519/jospt.2024.12106.


Assuntos
Artroscopia , Técnica Delphi , Luxação do Ombro , Humanos , Luxação do Ombro/cirurgia , Luxação do Ombro/reabilitação , Consenso , Guias de Prática Clínica como Assunto , Complicações Pós-Operatórias/prevenção & controle , Masculino
5.
J Orthop Surg Res ; 19(1): 159, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38429849

RESUMO

BACKGROUND: The shoulder joint is the most commonly dislocated joint in the human body, and the recurrence rate exceeds 50% after nonsurgical treatment. Although surgical treatment reduces the recurrence rate, there is controversy regarding the optimal surgical approach. Previous studies suggest that the Latarjet procedure yields favourable outcomes for specific populations at risk of recurrence, such as competitive athletes with significant glenoid defects. However, most of the existing related research consists of nonrandomized controlled trials with small sample sizes, and there is a lack of strong evidence regarding the efficacy and safety of the Latarjet procedure. METHODS: The PubMed, Embase, Cochrane Library, and Web of Science databases were systematically searched. Athletes with ≥ 20% glenoid defects were selected for inclusion. The following data were extracted: general patient information, instability rates, return to sports (RTS) rates, imaging features (graft positioning rate and graft healing rate), functional assessments [Rowe score, Athletic Shoulder Outcome Scoring System(ASOSS), visual analogue scale (VAS), forward flexion function, and external rotation function], and complications. RESULTS: After excluding suspected duplicate cases, a total of 5 studies were included in this meta-analysis. The studies involved a total of 255 patients, including 237 males (93%) and 18 females (7%). The average age at the time of surgery was 25.4 ± 8.5 years. All the studies had a minimum follow-up period of 2 years, with an average follow-up time of 48.7 ± 18.9 months. The pooled rate of return to sport (RTS) was 94.3% (95% CI: 87.3%, 98.8%), and 86.1% (95% CI: 78.2%, 92.5%) of patients returned to their preoperative level of activity. The pooled redislocation rate was 1.1% (95% CI: 0%, 3.8%). Regarding the imaging results, the combined graft retention rate was 92.1% (95% CI: 88.1%, 95.5%), and the graft healing rate was 92.1% (95% CI: 88%, 95.4%). Postoperative functional evaluation revealed that the combined Rowe score, ASOSS score, and VAS score were 93.7 ± 6.5 points, 88.5 ± 4.4 points, and 1.1 ± 10 points, respectively. The forward flexion and external rotation angles were 170.9 ± 6.9 degrees and 65.6 ± 4.5 degrees, respectively. After excluding one study with unclear complications, the combined complication rate was 9.4% (95% CI: 1.0%, 23.6%). CONCLUSION: For athletes with shoulder instability and a total of ≥ 20% glenoid bone defects, the Latarjet procedure can achieve excellent functional outcomes, with the majority of patients returning to preoperative levels of sports activity. This procedure also leads to a low recurrence rate. Therefore, the Latarjet procedure has been proven to be a safe and effective treatment.


Assuntos
Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Masculino , Feminino , Humanos , Adolescente , Adulto Jovem , Adulto , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Luxação do Ombro/diagnóstico por imagem , Luxação do Ombro/cirurgia , Instabilidade Articular/cirurgia , Escápula/cirurgia , Atletas
6.
Am J Sports Med ; 52(5): 1292-1298, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38506922

RESUMO

BACKGROUND: The glenoid track concept is used to determine preoperatively whether a Hill-Sachs defect is engaging or not. Currently, the glenoid track concept relies on measurements of bony structures as well as on the confines and elasticity of the rotator cuff as a reference point, which varies extensively among individuals and therefore limits the reliability and accuracy of this concept. PURPOSE: To evaluate the reliability of the global track concept, which determines the angular distance of the Hill-Sachs defect from the center of the articular surface of the humeral head as a new reference point with the help of an automated image analysis software and 3-dimensional analysis of the humeral head. STUDY DESIGN: Controlled laboratory study. METHODS: Computed tomography scans of 100 patients treated for anterior shoulder instability with different sizes of Hill-Sachs defects were evaluated manually by 2 orthopaedic surgeons independently using the software OsiriX as well as automatically by using a dedicated prototype software (ImFusion). Obtained manual and automated measurements included the Hill-Sachs length, Hill-Sachs width, and Hill-Sachs depth of the defect; the Hill-Sachs interval (HSI); and the glenoid width for the glenoid track concept, as well as the angular distance of the Hill-Sachs defect from the center of the articular surface of the humeral head (global track concept). The reliability of the different measurement techniques was compared by calculating intraclass correlation coefficients (ICCs). RESULTS: There was a significant difference for all obtained parameters comparing manual and automatic measurements. For manually obtained parameters, measurements referring to bony boundaries (glenoid width, Hill-Sachs length, and Hill-Sachs width) showed good to excellent agreement (ICC, 0.86, 0.82, and 0.62, respectively), while measurements referring to soft tissue boundaries (HSI and glenoid track; ICC, 0.56 and 0.53, respectively) or not directly identifiable reference points (center of articular surface and global track) only showed fair reliability (ICC middle excursion, 0.42). When the same parameters were measured with the help of an automated software, good reliability for the glenoid track concept and excellent reliability for the global track concept in the middle excursion were achieved. CONCLUSION: The present study showed that the more complex global track measurements of humeral defects are more reliable than the current standard HSI and glenoid track measurements. However, this is only true when automated software is used to perform the measurements. CLINICAL RELEVANCE: Future studies using the new proposed method in combination with an automated software need to be conducted to determine critical threshold values for defects prone to engagement.


Assuntos
Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Humanos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/cirurgia , Reprodutibilidade dos Testes , Ombro , Luxação do Ombro/diagnóstico por imagem , Luxação do Ombro/cirurgia , Cabeça do Úmero/diagnóstico por imagem , Cabeça do Úmero/cirurgia
7.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(2): 151-154, 2024 Feb 15.
Artigo em Chinês | MEDLINE | ID: mdl-38385226

RESUMO

Objective: To summarize the method and effectiveness of open reduction and internal fixation in the treatment of 4 cases of bipolar clavicle dislocations. Methods: Between June 2017 and June 2022, 4 patients with bipolar clavicle dislocations were admitted. There were 3 males and 1 female. The age ranged from 27 to 63 years, with an average age of 45 years. There were 2 cases of crushing injury of mine car, 1 case of traffic accident injury, and 1 case of heavy object injury. The time from injury to operation was 3-7 days, with an average of 5.0 days. The sternoclavicular joint dislocations were classified as Grade Ⅱ in 1 case and type Ⅲ in 3 cases, and anterior dislocation in 3 cases and posterior dislocation in 1 case. The acromioclavicular joint dislocations were classified as Tossy type Ⅱ in 2 cases and type Ⅲ in 2 cases. After open reduction, the sternoclavicular joint and acromioclavicular joint were fixed with lateral malleolus locking titanium plate and clavicular hook plate, respectively. Results: All operations were successfully completed without vascular or nerve injury. All incisions healed by first intention. All patients were followed up 12-18 months, with an average of 14 months. At last follow-up, the shoulder joint functions were rated as excellent in 3 cases and good in 1 case according to Rockwood score. During follow-up, there was no loosening of internal fixator or fracture. The internal fixators were removed in all patients at 5-7 months after operation (mean, 6 months), and no re-dislocation occurred after removal. Conclusion: For bipolar clavicle dislocation, open reduction combined with lateral malleolus locking titanium plate fixation of the sternoclavicular joint and clavicle hook plate fixation of the acromioclavicular joint can achieve good effectiveness. It has the advantages of simple operation, high safety, firm fixation, and fewer complications, and the shoulder function recovers well.


Assuntos
Articulação Acromioclavicular , Luxações Articulares , Luxação do Ombro , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Adulto , Clavícula/cirurgia , Clavícula/lesões , Titânio , Resultado do Tratamento , Luxações Articulares/cirurgia , Luxação do Ombro/cirurgia , Fixação Interna de Fraturas , Placas Ósseas , Articulação Acromioclavicular/cirurgia , Articulação Acromioclavicular/lesões
8.
BMC Musculoskelet Disord ; 25(1): 174, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38409002

RESUMO

PURPOSE: To compare the clinical efficacy of arthroscopic TightRope loop titanium button and clavicular hook plate in the treatment of acromioclavicular joint (ACJ) dislocation of Rockwood III/IV. METHODS: A retrospective analysis of patients with ACJ dislocation in our hospital from January 2018 to December 2020 was conducted. The patients were assigned to be treated with arthroscopic TightRope loop titanium button (TR group) or clavicular hook plate (HP group). The preoperative, intraoperative and postoperative data and imaging findings of the two groups were compared. RESULTS: A total of 58 eligible patients were enrolled in this study. Compared with HP group, TR group had shorter incision length and less blood loss during operation. Postoperative follow-up ranged from 12 to 24 months (mean 15.4 months). At 6 months and 12months postoperatively, compared with HP group, TR group had lower VAS and higher CMS, and the difference was statistically significant. At 12 months postoperatively, compared with HP group, TR group had lower ACJ gap and coracoclavicular joint(CCJ) distance, and the difference was statistically significant.In HP group, there were 3 cases of subacromial impact, 1 case of redislocation, 2 cases of traumatic arthritis and 2 cases of wound infection. There was 1 case of redislocation in TR group. CONCLUSIONS: Compared with clavicular hook plate, arthroscopic TightRope loop titanium button is minimally invasive, safe and effective in the treatment of ACJ dislocation, and has a good trend in clinical application.


Assuntos
Articulação Acromioclavicular , Luxações Articulares , Luxação do Ombro , Humanos , Estudos Retrospectivos , Luxações Articulares/cirurgia , Titânio , Articulação Acromioclavicular/diagnóstico por imagem , Articulação Acromioclavicular/cirurgia , Luxação do Ombro/cirurgia , Placas Ósseas , Resultado do Tratamento
9.
Knee Surg Sports Traumatol Arthrosc ; 32(3): 750-762, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38341626

RESUMO

PURPOSE: Adequate position of the bone block during arthroscopic Latarjet procedure is critical for an optimal functional outcome. However, this procedure is complex with a long learning curve. Our aim was to compare the bone block position between a dedicated glenoid posterior instrumentation and suture button fixation versus an anterior screw fixation, on a postoperative computed tomography (CT) scan. METHOD: Seventy-nine consecutive patients operated on for an anterior shoulder instability were included in this retrospective study. The same surgeon performed arthroscopically the Latarjet procedure either with an anterior drilling and screw fixation (Group A), or with a specific posterior glenoid guide pin, a posterior drilling, and a suture cortical button fixation (Group B). Evaluations were made by two independent observers. The position was evaluated by CT scan in the axial and sagittal planes. Learning curves with operative time, complications and clinical outcomes were assessed at a minimum of 2 years of follow-up. RESULTS: Thirty-five patients were included in Group A and 44 in Group B. In Group A, 27 bone blocks were flush (87.1%) and 38 in Group B (92.7%) (p < 0.01). In Group A, 72% of the bone block height was below the equator and 76%, in Group B (ns). The mean operating time was 123 ± 32.5 min in Group A and 95 ± 34.1 min in Group B (p < 0.0001). At the final follow-up, the mean aggregate Rowe score was respectively 94.6 ± 10.4 and 93.1 ± 9.8 points in Groups A and B. The mean aggregate Walch-Duplay score was respectively 94.2 ± 11.6 and 93.4 ± 10.6 points in Groups A and B. There were 11 complications (31.4%) in Group A and five complications (11.3%) in Group B (ns). CONCLUSION: The arthroscopic Latarjet procedure with a posterior drilling guided system and suture-button fixation allows more precise positioning in the axial plane than with anterior drilling and screw fixation. This posterior-guided procedure could reduce intraoperative and short-term complications. LEVEL OF EVIDENCE: Level IV.


Assuntos
Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Humanos , Articulação do Ombro/cirurgia , Estudos Retrospectivos , Instabilidade Articular/cirurgia , Artroscopia/métodos , Transplante Ósseo/métodos , Suturas , Luxação do Ombro/cirurgia
10.
Arthroscopy ; 40(5): 1431-1433, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38323954

RESUMO

Traumatic anterior shoulder dislocations can cause a myriad of injuries, each with their own unique set of challenges with respect to surgical management. The debate of whether open or arthroscopic management is the superior approach is one that predates most currently practicing orthopaedic surgeons yet remains one of the most actively researched areas of orthopaedics. Current trends favor arthroscopic management for anterior instability secondary to a Bankart lesion in patients without other risk factors for instability, such as critical glenoid bone loss. However, excellent results are not guaranteed following arthroscopic Bankart repair, particularly in athletes, due to high rates of recurrence. While the technique of inferior to superior capsular shift is not new, transitioning a historically open technique to the arthroscopic world may represent another tool in the glenohumeral instability management toolbox. While perspectives are evolving, more evidence supporting arthroscopic techniques like the capsular shift are needed to better identify appropriate patient populations.


Assuntos
Artroscopia , Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Humanos , Artroscopia/métodos , Instabilidade Articular/cirurgia , Luxação do Ombro/cirurgia , Articulação do Ombro/cirurgia , Lesões de Bankart/cirurgia , Traumatismos em Atletas/cirurgia , Cápsula Articular/cirurgia , Atletas
11.
Orthop Surg ; 16(3): 568-576, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38233358

RESUMO

OBJECTIVE: Endobutton technique could provide flexible coracoclavicular (CC) stabilization for acromioclavicular joint (ACJ) dislocation and achieved good clinical outcomes. However, the difficult part of this technique was placement of the Endobutton to the coracoid base. In this study, we designed an Endobutton installation device to place the Endobutton at the coracoid base. And we examined the clinical and radiographic outcomes of patients with acute Rockwood type III ACJ dislocation repaired with Endobutton using this device. METHODS: We designed an Endobutton installation device to place the Endobutton at the coracoid base to achieve CC stabilization. We retrospectively reviewed 42 patients with acute Rockwood type III ACJ dislocation who underwent CC stabilization with Endobuttons placed either using this novel device (group I, n = 19) or the traditional technique (CC stabilization without using special device, group II, n = 23) from January 2015 to April 2020. The two groups were compared regarding the operative time, intraoperative blood loss, and clinical and radiologic outcomes at final follow-up. The operation-related complications were also evaluated. The Student's t test and the Mann-Whitney U-test were used to compare differences in continuous variables. Differences in categorical variables were assessed with either the Pearson's chi-squared test or Fisher's exact test. RESULTS: Forty-two patients were clinically followed up for a minimum of 12 months. Compared with group II, group I had a significantly shorter mean operative time (56.05 ± 7.82 min vs. 65.87 ± 7.43 min, p < 0.01) and significantly lesser mean intraoperative blood loss (67.89 ± 14.75 mL vs. 94.78 ± 25.01 mL, p < 0.01). At final follow-up, there were no significant differences between the two groups in the visual analog scale score for pain, Oxford Shoulder Score, Disabilities of the Arm, Shoulder, and Hand score, and postoperative CC distance of the affected side. Loss of reduction occurred in four patients in group I and three patients in group II (p = 0.68); there were no other operation-related complications in either group. CONCLUSIONS: The Endobutton installation device makes placement of the Endobutton at the coracoid base easier and achieves satisfactory clinical and radiologic outcomes without additional complications in acute Rockwood type III ACJ dislocation.


Assuntos
Articulação Acromioclavicular , Luxações Articulares , Luxação do Ombro , Humanos , Luxações Articulares/cirurgia , Estudos Retrospectivos , Articulação Acromioclavicular/cirurgia , Perda Sanguínea Cirúrgica , Resultado do Tratamento , Luxação do Ombro/cirurgia
12.
Orthop Surg ; 16(3): 745-753, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38238248

RESUMO

BACKGROUND: Numerous studies indicate that glenoid bony augmentation raises the risk of complications during and after surgery. On the other hand, repairing the labrum alone in cases with subcritical glenoid bone loss results in recurrent instability and persistent apprehension. As a result, recent advancements in shoulder instability surgery prioritize fully restoring the anterior shoulder restraint. OPERATIVE TECHNIQUE: A novel method for treating recurrent anterior shoulder instability with subcritical glenoid bone loss and off-track Hill-Sachs lesion in skeletally immature patients is suggested: the use of dynamic anterior stabilization technique incorporating the long head of the biceps tendon onto the anterior glenoid rim via trans-subscapular transfer, in conjunction with Hill-Sachs remplissage. A practical, step-by-step surgical technique for a complete reconstruction of the anterior capsule-labral-ligamentous complex is provided. This involves utilizing a soft-tissue dynamic anterior sling, achieved through the trans-subscapularis transfer of the long head of the biceps tendon at the glenoid level. The procedure concludes with a Hill-Sachs remplissage to further prevent off-track events and alleviate apprehension. CONCLUSION: Dynamic anterior stabilization is a suitable approach for addressing recurring anterior shoulder instability in skeletally immature patients who have subcritical glenoid bone loss and bipolar bone lesions.


Assuntos
Doenças Ósseas Metabólicas , Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Humanos , Articulação do Ombro/cirurgia , Luxação do Ombro/cirurgia , Instabilidade Articular/cirurgia , Instabilidade Articular/etiologia , Artroscopia/métodos , Recidiva
13.
Arthroscopy ; 40(3): 699-701, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38219136

RESUMO

In patients with shoulder instability, arthroscopic Bankart procedure results in a high recurrence rate if there is associated bone loss, even small-to-moderate bone loss. The Latarjet procedure mitigates against recurrence in such cases but has greater short-term (30-day) complications than an arthroscopic Bankart and a greater rate of revision or reoperation. In truth, short-term complications are low with both procedures. That said, complications after arthroscopic Bankart are less likely to manifest in the short term, and possible future failure is generally not discovered until after a patient is released and returns to sports and/or greater levels of activity. The ultimate pros and cons of each procedure require long-term follow-up. That said, in the short term after Latarjet, surgeons should be mindful to monitor for early infection, hematoma, and hardware malposition or failure. In the long term after Latarjet, surgeons could monitor for graft resorption, nonunion of the graft, hardware prominence, and postsurgical arthritis.


Assuntos
Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Humanos , Ombro , Articulação do Ombro/cirurgia , Luxação do Ombro/cirurgia , Luxação do Ombro/complicações , Instabilidade Articular/cirurgia , Instabilidade Articular/etiologia , Artroscopia/efeitos adversos , Artroscopia/métodos , Estudos Retrospectivos , Recidiva
14.
Arthroscopy ; 40(2): 540-542, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38296450

RESUMO

Collision and contact sports athletes are at higher risk of shoulder dislocations. In collision sports such as boxing, ice hockey, rugby, football, and various martial arts, the athlete purposely hits or collides with other athletes or objects with substantial force, whereas in contact sports such as basketball, field hockey, wrestling, and soccer, the athlete makes regular contact with other athletes but with substantially less force. Return-to-sports rates following arthroscopic shoulder stabilization are above 90%. Risk factors for a recurrent shoulder dislocation include younger age, previous dislocations, generalized hyperlaxity, an instability severity index score above 3, off-track lesions, glenoid bone loss, and participation in contact and collision sports. However, data from a recent study have shown that the rate of recurrence varies among different contact sports as both kinematics and kinetics are clearly different. Ice hockey (ES, 0.72) has been identified as the collision sport with the highest recurrence rate. Wrestling (ES, 0.33), rugby (ES, 0.23), martial arts (ES, 0.20), and boxing (ES, 0.18) had similar recurrence rates, but the effect sizes were 3 times lower when compared to ice hockey. The lowest recurrence rates were observed in field hockey (ES, 0.04), football (ES, 0.06), and soccer (ES, 0.06). The sample size was sufficient, but the moderate risk of bias and study quality suggest that the true effect will most likely be markedly different from the estimated effect. Although common sense dictates that recurrence rates should be different, scientific evidence is not supporting this motion, and the findings should be viewed with some caution.


Assuntos
Luxações Articulares , Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Futebol , Humanos , Articulação do Ombro/cirurgia , Luxação do Ombro/cirurgia , Artroscopia/efeitos adversos , Instabilidade Articular/cirurgia , Recidiva , Estudos Retrospectivos
15.
Am J Sports Med ; 52(3): 613-623, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38284285

RESUMO

BACKGROUND: Quantitative analysis of the glenoid face knotless-type anchor placement for arthroscopic Bankart repair has not been reported. PURPOSE: To evaluate the clinical and radiologic outcomes after arthroscopic Bankart repair using knotless bioabsorbable anchors depending on the anchor location. STUDY DESIGN: Case series, Level of evidence, 4. METHODS: A total of 124 patients (113 men and 11 women; age, 25.6 ± 7.5 years; follow-up time, 46.5 ± 18.2 months [range, 6.2-75.5 months]) who underwent arthroscopic Bankart repair with the bioabsorbable knotless anchor between 2017 and 2021 were included in this study. Among them, 118 patients were observed for >2 years (mean, 48.2 ± 16.8 months [range, 24-75.5 months]) and were analyzed for final clinical and radiologic outcomes. Using postoperative 6-month magnetic resonance imaging, remnant glenoid (%) and labral height were measured. Shoulder range of motion (ROM), radiographic osteoarthritic change, dislocation, apprehension test, and return to sports were recorded. Three groups were established based on the remnant glenoid, which represented the percentage of the exposed glenoid anteroposterior diameter to the original diameter using the best-fit circle method-group A: lower quartile; group B: interquartile; and group C: upper quartile-and variables were analyzed. RESULTS: Overall, the remnant glenoid was 57% ± 6.4% (range, 41.5%-75%) after the surgery. Osteoarthritic change, dislocations, and positive apprehension tests were observed in 5 (4.2%), 4 (3.4%), and 12 (10.2%) patients, respectively. A total of 34 (28.8%) and 64 (54.2%) patients could return to sports without and with restrictions, respectively. Comparing groups A, B, and C, postoperative labral height (7 ± 1, 7 ± 2, and 7 ± 1 mm; P = .623), final osteoarthritic change (1, 4, and 0; P = .440), positive apprehension tests (5, 5, and 2; P = .387), and return to sports (complete/restricted/unable, 6/18/5, 19/29/11, 9/17/4; P = .769) were not different. All ROM were similar across the groups (all P > .054), except for external rotation (ER) at postoperative 6 months (41.3°± 12.8°; 50.2°± 18.5°; and 49.8°± 15.2°; P = .050). However, ER after 1 year was similar across the groups (all P > .544). In further analysis, patients with positive apprehension tests had lower labral height compared with others (5 [4-6] mm and 7 [6-8] mm; P < .001). CONCLUSION: In arthroscopic Bankart repair, the placement of knotless bioabsorbable anchors on the glenoid face, combined with the remplissage procedure or rotator interval closure, resulted in a low recurrence rate and moderate return to sports. However, most patients had some restrictions in returning to sports. Moreover, this technique was not associated with postoperative arthritis and shoulder stiffness, including ER deficit, which was not affected by the position of the anchor on the glenoid face for a minimum 2-year follow-up.


Assuntos
Luxações Articulares , Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Masculino , Humanos , Feminino , Adolescente , Adulto Jovem , Adulto , Luxação do Ombro/cirurgia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Implantes Absorvíveis , Resultado do Tratamento , Instabilidade Articular/cirurgia
16.
Am J Sports Med ; 52(3): 594-602, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38287784

RESUMO

BACKGROUND: A limited number of studies have reported the long-term effectiveness of and associated factors for recurrence of anterior shoulder instability after arthroscopic Bankart repair (ABR). PURPOSE: To report the long-term clinical outcomes after ABR in a recreational sports population and identify the associated factors that influence the final instability status. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: A retrospective study was performed in patients treated with ABR between 2007 and 2013 by a single surgeon. Patient data, magnetic resonance imaging measurements of bone loss and glenoid track, and intra- and perioperative factors were analyzed. After a minimum follow-up of 10 years, patient-reported outcomes including the Western Ontario Shoulder Instability Index score, the Rowe score, the visual analog scale for pain and function, the American Shoulder and Elbow Surgeons score, and sports activity were assessed. The current instability status was classified into 3 groups: stable, apprehensive, and redislocated. These groups were statistically compared with respect to outcomes and associated factors. RESULTS: A total of 100 patients with a mean age of 22.4 ± 5.5 years and a mean follow-up of 12.7 ± 2.1 years were included. At the final follow-up, 38 patients (38%) showed recurrent symptoms: 19 patients (19%) with subjective apprehension and 19 patients (19%) with redislocation, including 10 patients (10%) with revision surgery. At the final follow-up, the redislocated group showed the lowest patient-reported outcomes and return to sports (both P < .001). The apprehensive group also showed a lower Western Ontario Shoulder Instability Index score (P = .011), Rowe score (P = .003), American Shoulder and Elbow Surgeons score (P = .027), and return to sports (P = .005) than the stable group. Participation in contact sports (P = .026), glenoid bone loss (P = .005), size of Hill-Sachs lesion (P = .009), and off-track lesions (P = .016) were all associated with recurrent symptoms, whereas age <20 years (P = .012), participation in contact sports (P = .003), and off-track lesions (P = .042) were associated with redislocation. CONCLUSION: After long-term follow-up in a recreational sports population, ABR demonstrated a 19% rate of subjective apprehension and 19% rate of redislocation, with a gradual decline in clinical outcomes and sports activity over time. Therefore, candidates for ABR should be selected based on consideration of risk factors such as off-track lesions, age <20 years, and participation in contact sports.


Assuntos
Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Humanos , Adolescente , Adulto Jovem , Adulto , Articulação do Ombro/cirurgia , Luxação do Ombro/cirurgia , Seguimentos , Estudos Retrospectivos
17.
Am J Sports Med ; 52(1): 181-189, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38164666

RESUMO

BACKGROUND: The glenoid track concept for shoulder instability primarily describes the medial-lateral relationship between a Hill-Sachs lesion and the glenoid. However, the Hill-Sachs position in the craniocaudal dimension has not been thoroughly studied. HYPOTHESIS: Hill-Sachs lesions with greater inferior extension are associated with increased risk of recurrent instability after primary arthroscopic Bankart repair. STUDY DESIGN: Case-control study; Level of evidence, 3. METHODS: The authors performed a retrospective analysis of patients with on-track Hill-Sachs lesions who underwent primary arthroscopic Bankart repair (without remplissage) between 2007 and 2019 and had a minimum 2-year follow-up. Recurrent instability was defined as recurrent dislocation or subluxation after the index procedure. The craniocaudal position of the Hill-Sachs lesion was measured against the midhumeral axis on sagittal magnetic resonance imaging (MRI) using either a Hill-Sachs bisecting line through the humeral head center (sagittal midpoint angle [SMA], a measure of Hill-Sachs craniocaudal position) or a line tangent to the inferior Hill-Sachs edge (lower-edge angle [LEA], a measure of Hill-Sachs caudal extension). Univariate and multivariate regression were used to determine the predictive value of both SMA and LEA for recurrent instability. RESULTS: In total, 176 patients were included with a mean age of 20.6 years, mean follow-up of 5.9 years, and contact sport participation of 69.3%. Of these patients, 42 (23.9%) experienced recurrent instability (30 dislocations, 12 subluxations) at a mean time of 1.7 years after surgery. Recurrent instability was found to be significantly associated with LEA >90° (ie, Hill-Sachs lesions extending below the humeral head equator), with an OR of 3.29 (P = .022). SMA predicted recurrent instability to a lesser degree (OR, 2.22; P = .052). Post hoc evaluation demonstrated that LEA >90° predicted recurrent dislocations (subset of recurrent instability) with an OR of 4.80 (P = .003). LEA and SMA were found to be collinear with Hill-Sachs interval and distance to dislocation, suggesting that greater LEA and SMA proportionally reflect lesion severity in both the craniocaudal and medial-lateral dimensions. CONCLUSION: Inferior extension of an otherwise on-track Hill-Sachs lesion is a highly predictive risk factor for recurrent instability after primary arthroscopic Bankart repair. Evaluation of Hill-Sachs extension below the humeral equator (inferior equatorial extension) on sagittal MRI is a clinically facile screening tool for higher-risk lesions with subcritical glenoid bone loss. This threshold for critical humeral bone loss may inform surgical stratification for procedures such as remplissage or other approaches for at-risk on-track lesions.


Assuntos
Lesões de Bankart , Luxações Articulares , Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Humanos , Adulto Jovem , Adulto , Luxação do Ombro/diagnóstico por imagem , Luxação do Ombro/cirurgia , Luxação do Ombro/complicações , Lesões de Bankart/diagnóstico por imagem , Lesões de Bankart/cirurgia , Lesões de Bankart/complicações , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/cirurgia , Instabilidade Articular/etiologia , Estudos Retrospectivos , Estudos de Casos e Controles , Seguimentos , Artroscopia/métodos , Cabeça do Úmero/diagnóstico por imagem , Cabeça do Úmero/cirurgia , Recidiva
18.
Am J Sports Med ; 52(1): 190-200, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38164667

RESUMO

BACKGROUND: The role of arthroscopic Latarjet as a revision surgery after failed arthroscopic Bankart repair has yet to be established. PURPOSE: To compare clinical outcomes, recurrences, and complication rates of arthroscopic Latarjet as a revision procedure after failed arthroscopic Bankart repair versus arthroscopic Latarjet as a primary procedure. DESIGN: Cohort study; Level of evidence, 3. METHODS: This is a retrospective study of prospectively collected data of patients who were diagnosed with anterior shoulder instability and underwent arthroscopic Latarjet stabilization between 2009 and 2018. Patients were separated into 2 groups depending on whether Latarjet was performed after a previous instability surgery (revision) or as a primary surgery (primary). Rowe score, Western Ontario Shoulder Instability Index (WOSI), Constant-Murley Shoulder Outcome (CMSO) score, and Single Assessment Numeric Evaluation (SANE) were assessed pre- and postoperatively with a minimum 24 months of follow-up. In addition, pre- and postoperative levels of sports activity, dislocations, subluxations, and complications were assessed. RESULTS: A total of 97 patients (n = 62 revision; n = 35 primary), with a mean age of 31.0 ± 8.8 and 29.4 ± 7.6 years old in the revision and primary Latajet group, respectively, met the inclusion criteria. The mean follow-up in the revision group was 32 months (24-53) and 35.5 months (27.7-42.2) in the primary Latarjet group. No significant differences between groups were observed in Rowe score (revision = 91.4, primary = 94.1; P = .223), CMSO score (revision = 90.7, primary = 94; P = .105), and SANE (revision = 85.8, primary = 87.3; P = .683) postoperatively. However, the postoperative difference in the WOSI score between the revision and primary Latarjet groups was nearly significant (510 ± 334 vs 403 ± 343, respectively; P = .05). Four (6.4%) postoperative dislocations were reported in the revision and 1 (2.8%) in the primary Latarjet group (P = .14). Patients in the revision group had a lower return to the previous level of sports participation (P = .008) and decreased external rotation with the arm by the side compared with the primary Latarjet group (P = .000). CONCLUSION: Arthroscopic Latarjet as a revision surgery is a reasonable surgical option in failed Bankart repair cases. The decision to perform arthroscopic Latarjet stabilization as a revision surgery should not be influenced by the potential risk of future complications as it provides comparable clinical outcomes to the primary Latarjet procedure with a low postoperative recurrence rate. However, a decreased level of postoperative sports participation and external rotation with the arm by the side can be expected.


Assuntos
Luxações Articulares , Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Humanos , Adulto Jovem , Adulto , Luxação do Ombro/cirurgia , Luxação do Ombro/diagnóstico , Articulação do Ombro/cirurgia , Estudos de Coortes , Estudos Retrospectivos , Instabilidade Articular/cirurgia , Instabilidade Articular/diagnóstico , Reoperação , Artroscopia/métodos , Luxações Articulares/cirurgia , Recidiva
19.
Am J Sports Med ; 52(1): 174-180, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38164674

RESUMO

BACKGROUND: There is scarce literature on clinically significant values after arthroscopic Bankart repair (ABR). PURPOSE: To determine the minimal clinically important difference (MCID) and the patient acceptable symptom state (PASS) thresholds at 1 year for the Rowe and Athletic Shoulder Outcome Scoring System (ASOSS) scores after ABR and to determine the effect of patient characteristics on these metrics after ABR. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: A retrospective review of patients undergoing ABR from a single institution between January 2017 and January 2020 was performed. Patients with at least 1 episode of instability and a minimum follow-up of 12 months were included. The exclusion criteria were as follows: bony defects of >20% on the anteroinferior portion of the glenoid based on a preoperative computed tomography scan; engaging Hill-Sachs lesions at 90° of abduction and 90° of external rotation based on an arthroscopic examination; previous surgery on the same shoulder; multidirectional instability or concomitant repair of full-thickness rotator cuff tears; superior labral anterior to posterior lesions; posterior labral tears; or humeral avulsion of the glenohumeral ligament lesions. Patient-reported outcome measures were collected both preoperatively and 1-year postoperatively. Delta was defined as the change between preoperative and 1-year postoperative scores. Distribution-based (one-half the standard deviation of the difference between pre- and postoperative outcome scores) and anchored-based approaches (response to a satisfaction question at 1 year) were used to estimate the MCID and the PASS, respectively. The optimal cutoff point, where sensitivity and specificity were maximized, and the percentage of patients achieving those thresholds were also calculated. RESULTS: Overall, 190 patients were included. The distribution-based MCID for the Rowe and ASOSS scores were calculated to be 8.2 and 8.7, respectively. The rate of patients who achieved MCID thresholds was 96% for the Rowe and 96% for ASOSS scores. The PASS threshold for the Rowe and ASOSS scores were ≥80 and ≥90, respectively. The rate of patients who achieved PASS scores after ABR were 86% and 83%, respectively. The MCID and PASS values showed great variability based on sex (men: 8.5 and ≥85 for Rowe / 8.9 and ≥90 for ASOSS, respectively, vs women: 6.7 and ≥73 for Rowe / 8.1 and ≥75 for ASOSS), age (≥21: 8.4 and ≥80 / 9.2 and ≥90 vs <21: 7.8 and ≥75 / 7.7 and ≥85), sports participation (sports: 8.8 and ≥85 / 9.5 and ≥90 vs no sports: 8.1 and ≥75 / 8.6 and ≥80), and type of athlete (competitive: 8.4 and ≥85 / 8.9 and ≥87 vs recreational: 7.5 and ≥73 / 8.1 and ≥68). CONCLUSION: This study identified the MCID and PASS thresholds for the Rowe and ASOSS scores at 1 year after ABR. However, these values showed great variability when accounting for different patient characteristics such as sex, age, sports participation, and type of athlete, highlighting the importance of considering individual patient-specific characteristics for optimal treatment decision-making and ensuring treatment success tailored to each patient's unique needs and expectations.


Assuntos
Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Masculino , Humanos , Feminino , Diferença Mínima Clinicamente Importante , Artroscopia/métodos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Artroplastia , Estudos Retrospectivos , Resultado do Tratamento , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/cirurgia , Instabilidade Articular/complicações , Luxação do Ombro/cirurgia
20.
BMC Musculoskelet Disord ; 25(1): 29, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38166887

RESUMO

BACKGROUND: To evaluate the outcome of shoulder arthroscopy-assisted implantation of three-dimensional (3D)-printed titanium pads for recurrent shoulder dislocation with glenoid bone defects. METHODS: From June 2019 to May 2020, the clinical efficacy of 3D printed titanium pad implantation assisted by shoulder arthroscopy, for the treatment of recurrent shoulder dislocations with shoulder glenoid defects was retrospectively analyzed. The American Shoulder and Elbow Surgeons (ASES) shoulder, Rowe, and Constant scores were recorded before surgery and at 3 months, 6 months, 1 year, and 2 years after surgery. 3D computed tomography (CT) and magnetic resonance imaging were used to evaluate the location of the glenoid pad, bone ingrowth, joint degeneration, and osteochondral damage. RESULTS: The mean age of the 12 patients was 21.4 (19-24) years and the mean follow-up time was 27.6 (24-35) months. The Visual Analog Scale score significantly improved from 5.67 ± 1.98 preoperatively to 0.83 ± 0.58 postoperatively (p = 0.012). The postoperative ASES score was significantly increased to 87.91 ± 3.47 compared with preoperative ASES score (46.79 ± 6.45) (p < 0.01). Rowe and Constant scores also improved from 22.5 ± 12.34 and 56.58 ± 7.59 preoperatively to 90.83 ± 4.69 and 90.17 ± 1.89 at 2 years postoperatively, respectively. CT performed 2 years after surgery showed that the pad perfectly replenished the bone-defective part of the shoulder glenoid and restored the articular surface curvature of the shoulder glenoid in the anterior-posterior direction, and the bone around the central riser of the pad was tightly united. Magnetic resonance imaging 2 years after surgery showed that the humeral head osteochondral bone was intact, and there was no obvious osteochondral damage. CONCLUSIONS: 3D printed titanium pads are a reliable, safe, and effective surgical procedure for treating recurrent shoulder dislocations with glenoid bone defects.


Assuntos
Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Humanos , Adulto Jovem , Adulto , Luxação do Ombro/diagnóstico por imagem , Luxação do Ombro/cirurgia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Titânio , Seguimentos , Estudos Retrospectivos , Instabilidade Articular/cirurgia , Artroscopia/métodos , Impressão Tridimensional , Recidiva
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA